NIGHTSHIFT
Stage
Reported
Diagnosed
RMA Filed
Scheduled
Replaced
Closed
🛡
Cardinal RMA approved · replacement IGU received Apr 25 · install Fri May 1, 10 AM · no charge to builder
Original Install (Sep 2024)
View J-2024-0731
Job #J-2024-0731
Date installedSep 14, 2024
TechMike Henson
Original cost$680
IGU specCardinal LoE-366, argon
Lot/batchCIG-2024-W34
Mfr dateAug 22, 2024
DOH (date of hermetic)Aug 22, 2024
Root Cause Diagnosis
TestResultConclusion
Visual condensation between panesFailedInternal moisture present
Spacer integrity (warm-edge)CompromisedDesiccant saturated — primary seal breach
Argon retention testBelow spec<30% argon remaining
Glass surface (any impact)CleanNo customer-caused damage
Frame & glazing compoundIntactWorkmanship OK
Conclusion: Manufacturing defect (primary seal failure). Within Cardinal IG 10-year seal warranty (ASTM E2190). RMA submitted Apr 18 · approved Apr 22 · replacement free of charge to GD. No labor reimbursement from Cardinal — absorbed under our 2-year workmanship goodwill.
Replacement Material
SKUItemVendorRMA / CostStatus
CRD-IGU-3660 IGU 36x60 LoE-366 argon, warm-edge Cardinal IG (RMA replacement) $0 (RMA) Received Apr 25
CRL-GZ-30 Glazing tape 3/8" (consumable) CRL $8 Stocked
DOW-995-BLK Dow 995 silicone (consumable) Stock $12 Loaded
Internal cost to GD: $148 ($20 consumables + $128 labor) · absorbed under workmanship warranty.
Credit Memo to Watts Construction
CM-2026-0033
Issued Apr 23, 2026
Posted
Goodwill credit for diagnostic visit (Apr 17) plus full replacement labor and material covered under warranty. No invoice will be sent to Watts Construction.
Credit value $680.00
Activity
📦
Cardinal IGApr 25, 11:30 AM
Replacement IGU received · RMA CIG-RMA-26-04812 · verified lot/batch
💵
Donna (CSR)Apr 23, 4:14 PM
Posted credit memo CM-2026-0033 · $680 goodwill
Cardinal IGApr 22, 9:18 AM
RMA approved · replacement IGU shipping no-charge
📄
Mike HensonApr 18, 2:48 PM
RMA filed with Cardinal · included photos + lot/batch
📍
Mike HensonApr 17, 10:00 AM
Diagnostic visit · confirmed seal failure · no customer fault
📧
Travis WattsApr 16, 8:32 AM
Reported foggy IGU on Lot 8 dining room window · "looks like a failed seal"