NIGHTSHIFT
← Glass Schedule / Vapors & Kratom / 360 Beaumont Centre Dr
OP-01

Storefront Lite L1

⚠ Broken — Replacement Queued
Vapors & Kratom · 360 Beaumont Centre Dr, Lexington KY 40513 · Leftmost storefront bay · Fixed lite
⚡ Order Replacement
Opening Photo — OP-01 Highlighted
Broken Pane
Vape shop storefront — OP-01 highlighted
OP-01
Geometry
👷 Tech verified
Width
47-3/4"
×
Height
84"
Area
27.9
sqft
Sill Height (AFF)18"
PositionLeftmost storefront bay
ShapeRectangular
Glazing Pocket Depth1/2"
Bite (glass into frame)5/8"
Verified by Mike Henson · 2026-04-29
Glass Makeup
👷 Tech verified
Thickness1/4"
TypeTempered (safety glazing zone)
Tint / CoatingClear — no coating
IG UnitNo — monolithic
Float SupplierCardinal IG (lite)
TemperingAnchor-Ventana (local)
Cut Size Deduct-3/16" all sides
Cut NotePer Cardinal IG standard spec
Verified by Mike Henson · 2026-04-29
Frame
📐 From drawing
Frame TypeAluminum storefront
FinishDark bronze anodized
Anodize ClassClass I (0.7 mil)
SeriesKawneer Trifab 451T
ManufacturerKawneer (Arconic)
Mfr Year2003
System Width4-1/2"
Thermal BreakNo — standard storefront
Source: 2003 Beaumont Centre permit drawings · LFUCG permit 2003-BC-0441
Hardware
📞 Customer reported
N/A — Fixed Lite
Fixed lites have no operable hardware. Glazing system uses:
· Structural silicone (perimeter back-bed)
· Wet-glazed with dense foam tape setting blocks
· No hinges, no operators, no closer
Glazing MethodWet-bed structural silicone
Setting BlocksDense foam · 2" from corners
Sealant (exterior)Dow 795 silicone
Reported by Derrick Okafor on initial survey call
Code & Compliance Tags
⚡ Tempered Required — Safety Glazing Zone Egress: No Historic: No IBC §2406 Compliant Fire-Rated: No
Safety glazing basis: IBC §2406.4 — Glazing in doors and sidelights with sill height <18" AFF and subject to human impact (storefront adjacent to pedestrian path). Tempered required at this location per code.
Replacement glass must also be tempered. No low-iron substitution without re-engineering approval.
Opening History
2026-04-29 13:14
Broken reported — customer phoned
Derrick Okafor called CSR line. Shards on sidewalk, safety tape applied by tenant. Opened recall flow immediately.
2026-04-29 13:42
PO #PO-2026-0234 created
1/4" tempered clear · 47-5/8 × 83-5/8 cut size · Cardinal IG via Anchor-Ventana
View PO →
2026-04-29 09:15
Dimensions verified on-site — Mike Henson
All 5 openings measured. OP-01 dims: 47-3/4 × 84. No deviations from AI prebuild.
2026-04-28
Opening auto-populated by AI Doc Prebuild
Dimensions estimated from Google Street View (Apr 2025 imagery) + county parcel records. Confidence: 92%.
View doc prebuild detail →
2019-04
Perimeter sealant resealed
Job J-2019-0184 · Terry Banks. Dow 795 reapplied, no glass replacement needed.
2003-08
Initial installation
Kawneer 451T storefront system installed. 4 lites + entry door. Job J-2003-0012. Frame: dark bronze Class I anodized.
View original job →
Linked Jobs, Estimates & POs
Estimate
OP-01 Tempered Replacement
Auto-generated · $680
Pending Approval
Purchase Order
PO-2026-0234
1/4" Tempered Clear
Cardinal IG via Anchor-Ventana
Ordered
Job
Storefront lite replacement
Mike Henson · Apr 30, 2026
Scheduled